firefighting
Professional Firefighting
Firefighting equipment materials should be used only with certified products, and firefighting equipment constructed in clean rooms is not easy to inspect and manage, so more professional construction is required.
Sprinkler construction
Criteria for installing sprinklers
+ Logistics terminal among sales facilities, transportation facilities, and warehouse facilities:
The number of floors is 3 or more. All floors are 6,000 m2 or higher.
The number of floors is 4 or higher. All floors are 5,000 m2 or higher.
+ Among medical facilities, general medical institutions, elderly facilities, and training facilities for accommodation.
All floors above 600m2.
+ Cultural and assembly facilities, religious facilities, and sports facilities (excluding zoos, botanical gardens, temples, ancestral rites, shrines, and water play facilities):
Number of people: 100 or more.
The floor area used for movie theaters.
Underground floor or windowless floor: All floors above 500 m2.
In the case of other floors: All floors over 1,000 m2.
+ If you’re one the basement floor, the floor without windows
the floor above 4 floors, all floors above 300 m2. The entire floor of 500 m2 or higher If not.
A rack-type warehouse with a ceiling or a height of more than 10m
(a device for transporting a storage by a shelf or elevator)
+ Among medical facilities, mental medical institutions, elderly facilities, and training facilities for accommodation.
All floors above 600 m2
More than 1,000 m2 in the basement (excluding tunnels).
+ The floor area (excluding frozen warehouses and livestock houses) which is the basement floor, the windowless floor, or the 4th floor as specific firefighting targets.
Above 1,000 m2
+ Dormitory or complex building for accommodation of students in educational research facilities and training facilities.
All floors above 5,500 m2
+ Campuses and military facilities.
Shelter, prison, detention center, juvenile center.
Protection facilities (in the case of foreign shelters, it is limited to the living space of the ward)
Except in cases where the protection facility is in the leased building.
Firefighting facility construction
Alarm equipment construction
- Automation re-detection equipment
- Emergency broadcasting equipment
- Emergency warning equipment
- Automation breaking news facility
- Short circuit alarm
Fire extinguishing equipment construction
- Indoor fire hydrant
- Outdoor fire hydrant
- Sprinkler equipment
- Water-spray type fire extinguishing equipment
- Foam Fire Extinguishing equipment
- Carbon dioxide fire extinguishing equipment.
- Halogen compound fire extinguishing equipment
- Powder fire extinguishing equipment
Fire Extinguishing Activity Facility Construction
- Smoke-free equipment
- Connection to the water supply pipe
- Connection to the water supply facility
- Emergency outlet facilities
- Wireless communication equipment
- Combustion prevention equipment
Evacuation Facility Construction
- Evacuation equipment
- A life-saving device
- Exit light/ Exit Sign
- Emergency lighting

Firefighting Equipment Construction
- Sprinkler equipment
- Earthquake-related facilities
- Indoor and outdoor fire hydrant facilities
- And other fire extinguishing facilities

Evacuation Facility Construction
- Exit Light
- Evacuation equipment construction

Alarm Equipment Construction
- Emergency broadcast/alarm
- Automatic Fire alarm system
- Automation re-detection equipment